Abstract

Objective To explore the accuracy of double modality fusion between CT and MRI for human head, based on pair anatomical points registration. Methods CT and MRI were approached in 4 patients, digital imaging and communications in medicine (DICOM) files were loaded on 3D Slicer (version 4. 8.1), the surface and brain were reconstructed automatically with volume rendering as reconstructed models, 10 surface characters were tested with localization error and would be used as fiducial points, 8 of the points would be chosen as pairpoints for registration according the localizing error after 5 localizations, 5 registration groups based on 4, 5, 6, 7, 8 fiducial points were divided. Singular value decomposition (SVD) was employed for registration as a basic algorithm, and fiducial registration error (FRE) was used to evaluate the registration error. Results FRE values of double modality fusion were 2.68-6.54 mm. FRE values of 4, 5, 6, 7, 8 fiducial points were (5.14±0.97)mm, (4.71±0.64)mm, (4.45±0.59)mm, (4.13±0.55)mm, (3.54±0.72)mm respectively. There was no statistical difference between neighbor groups, while in 4 and 8 points groups, the FRE values were different statistically. Conclusion Surface anatomic characters can be used for double modality fusion between CT and MRI; FRE values after CT-MRI double modality fusion are reduced with the increase of points.

Key words

Head / Double modality / Pair-point registration / Anatomic character / Computed tomography / Magnetic resonance imaging / Human

Cite this article

Download Citations
JI Da-feng MA Zhong-bin. Double modality fusion between CT and MRI for human head based on surface anatomic characters[J]. Acta Anatomica Sinica. 2019, 50(5): 638-644 https://doi.org/10.16098/j.issn.0529-1356.2019.05.016

References

 [1] Sekine T,Barbosa FG,Kuhn FP,et al. PET+MR versus PET/CT in the initial staing of head and neck cancer, using a trimodality PET/CT+MR system[J]. Clin Imaging,2017,42:232-239.
 [2] Mocnik D, Ibragimov B, Xing L,et al. Segmentation of parotid glands from registered CT and MR images[J]. Phys Med,2018,52:33-41.
 [3] Bannas P,Pickhardt PJ. MR evaluation of the nontraumatic acute abdomen with CT correction[J]. Radiol Clin North Am,2015,53(6):1327-1339.
 [4] Zhang JW, Li T, Sun JZh. Multimodality medical image registration based on dividing rectangles[J].Journal of Image and Graphics, 2008,13(4):749-755. (in Chinese)
张加万,李谭,孙济洲. 基于Dividing Rectangles的多模态医学图像配准算法[J]. 中国图象图形学报,2008, 13(4):749-755.
 [5] Donoso FA, Austin KJ, McAree PR. Three new iterative closest point variant-methods that improve scan matching for surface mining terrain[J]. Robotics and Autonomous System, 2017, 95:117-128.
 [6] Xiang L, Wang Q, Nie D, et al. Deep embedding convolutional neural network for synthesizing CT image from T1-weighted MR image[J]. Med Image Anal, 2018, 47:31-44.
 [7] Wang MN. Analysis of the errors in neuronavigation and research on imporving the accuracy of space registration[D]. Fudan University, 2011. (in Chinese)
王满宁. 神经导航误差分析与提高空间配准精度的研究[D].复旦大学,2011.
 [8] Zhang Y, Gu D, Ji D. The design and application of a customized navigation board for lumbar disc ablation[J]. Comp Assisted Surg, 2017, 22(S1):305-311.
 [9] Dafeng J, Yuan D, Manning W, et al. Accuracy analysis of line-based registration for image guided neurosurgery at different operating areas-a phantom study[J]. Comp Assisted Surg, 2017, 22(S1):148-156.
 [10]Fitzpatrick JM, West JB. The distribution of target registration error in rigid-body point-based registration[J]. IEEE Trans Med Imaging, 2001, 20(9):917-927.
PDF(899 KB)

Accesses

Citation

Detail

Sections
Recommended

/