利用数字散斑法测量股骨干骨折加压钢板内固定下的位移和形变

邹庆峰;陈元晓;李建云;吴加权;马琨;陈英杰

解剖学报 ›› 2010, Vol. 41 ›› Issue (1) : 157-159.

欢迎访问《解剖学报》官方网站!今天是 English
解剖学报 ›› 2010, Vol. 41 ›› Issue (1) : 157-159. DOI: 10.3969/j.issn.0529-1356.2010.01.031
论著

利用数字散斑法测量股骨干骨折加压钢板内固定下的位移和形变

  • 邹庆峰1;陈元晓2;李建云3;吴加权4;马琨4;陈英杰1*

作者信息 +

Measuring the displacement and deformation under the internal fixation with compressing steel plate for femoral fractures by digital speckle method

Author information +
文章历史 +

Abstract

Objective Measuring the displacement and deformation of the fifth screw under different tensile force before or after adultal internal fixation with compressing steel plate for femoral fractuer by digital speckle correlation method.And analysis of the displacement and deformation after reducing the number of screws.Aimed at providing a theoretical basis for clinical femoral internal fixation with compressing steel plate about the number of screws. Methods Taking the antisepsis femoral specimen of grown-ups, embedding and fixing with tooth powder after removing the soft tissue, producing a fixed model in the 1/2 femur.Fixing steel plate below the lateral femur subperiosteal with five screws through the fourth floor of cortical bone on both sides of the fractures, samples were divided into 10 states, group A-J were measured by orders, under the rally of 400 N,500N , measuring the displayment of the fifth screw with CSS-44100-e-universal test machine for loading rally experiment ,and automatic data processing. Results For analysis of variance, the mean displacement measurements of the fifth screw under rally of 400N,500N, B-J group and A group have significant differences(EM>P/EM><0.05).The mean deformation measurements of the fifth screw - under rally of 400N,500N, group A and group F-J group have significant differences(EM>P/EM><0.05); group A and B-E group have no significant differences.Conclusion In a certain range, the fracture displacement and the numuber of the screws show negative correlation. The screws near the fracture line for femoral compression plate internal fixation of femoral fractuer is easily broken because

关键词

股骨干 / 骨折 / 钢板内固定 / 生物力学 /

Key words

Shaft of femur / Fracture / Internal fixation with compressing steel plate / Biomechanics / Human

引用本文

导出引用
邹庆峰;陈元晓;李建云;吴加权;马琨;陈英杰. 利用数字散斑法测量股骨干骨折加压钢板内固定下的位移和形变[J]. 解剖学报. 2010, 41(1): 157-159 https://doi.org/10.3969/j.issn.0529-1356.2010.01.031
Measuring the displacement and deformation under the internal fixation with compressing steel plate for femoral fractures by digital speckle method[J]. Acta Anatomica Sinica. 2010, 41(1): 157-159 https://doi.org/10.3969/j.issn.0529-1356.2010.01.031
中图分类号: R322.33   

Accesses

Citation

Detail

段落导航