经喙突肩胛骨关节盂螺钉内固定的最优化计算机辅助测量

陈亿民;洪俊毅;毕大卫;马海涛;廖胜辉;王辉;祖罡

解剖学报 ›› 2010, Vol. 41 ›› Issue (1) : 153-156.

欢迎访问《解剖学报》官方网站!今天是 English
解剖学报 ›› 2010, Vol. 41 ›› Issue (1) : 153-156. DOI: 10.3969/j.issn.0529-1356.2010.01.030
论著

经喙突肩胛骨关节盂螺钉内固定的最优化计算机辅助测量

  • 陈亿民1;洪俊毅1;毕大卫1;马海涛1;廖胜辉2* ;王辉1;祖罡1
作者信息 +

Optimal computer aided measure for screw internal fixation in the cavitas glenoidalis through human coracoid process of scapula

Author information +
文章历史 +

Abstract

Objective To investigate a special optimization technique for computer aided measure, and provide anatomical basis for screw internal fixation in the cavitas glenoidalis through the coracoid process of scapula. Methods Thirty accurate scapula models were reconstructed from CT data sets. First, special optimization objective function was designed for single screw internal fixation configuration, and the optimal placement of screw was found automatically under constraints. Then, the placements of double screws internal fixation configuration were searched taking advantage of principal component analysis. Finally, statistical measure data were provided according to new anatomical reference landmarks for clinical use. Results For single screw internal fixation configuration, the distance from the optimal screw entry point P to the acromion process point X was (39.15±2.28) mm, to the coracoid process point Y was (28.66±2.68) mm, to the angulus superior point Z was (61.13±6.57) mm; The angle was (81.27±7.15)° between PX and PY, and (133.27±6.84)° between PX and PZ. The mean inclination of the lag screw was (104.08±4.41)° for the angle with line PX, (101.29±3.51)° with line PY, and (76.23±5.03)° with line PZ. For double screws configuration, the distance from the original single screw entry point P to the screw entry point E was (5.12±1.37)mm,to the screw entry point F was (3.88±0.94)mm. The angle between the long axis of coracoid process and li

关键词

肩胛骨 / 关节盂 / 喙突 / 螺钉内固定 / 计算机辅助测量 / 最优化方法 /

Key words

Scapula / Cavitas glenoidalis / Coracoid process / Screw internal fixation / Computer aided measure / Optimization technique / Human

引用本文

导出引用
陈亿民;洪俊毅;毕大卫;马海涛;廖胜辉;王辉;祖罡. 经喙突肩胛骨关节盂螺钉内固定的最优化计算机辅助测量[J]. 解剖学报. 2010, 41(1): 153-156 https://doi.org/10.3969/j.issn.0529-1356.2010.01.030
Optimal computer aided measure for screw internal fixation in the cavitas glenoidalis through human coracoid process of scapula[J]. Acta Anatomica Sinica. 2010, 41(1): 153-156 https://doi.org/10.3969/j.issn.0529-1356.2010.01.030
中图分类号: R323.5    R322.3   

Accesses

Citation

Detail

段落导航
相关文章

/